home *** CD-ROM | disk | FTP | other *** search
/ QRZ! Ham Radio 8 / QRZ Ham Radio Callsign Database - Volume 8.iso / mac / files / infodata / oe3000.txt < prev    next >
Text File  |  1996-06-25  |  21KB  |  375 lines

  1. To: bowen@cs.buffalo.edu
  2. Subject: OE 3000A Handicounter Review
  3. From: bmork@opus-ovh.spk.wa.us (Brian)
  4. Date: Wed, 23 Mar 94 17:33:32 GMT
  5.  
  6. Optoelectronics 3000A Product Review - September 1993
  7. Copyright (c) 93,94 Brian Mork -- "not to make money, but to keep it that 
  8. way for others."
  9.  
  10. >>> HISTORY
  11. June 19th of 1993, I distributed a product review of Optoelectron-
  12. ics' 3000A handicounter.  It had bad dBm calculations.  A 29 July 
  13. distribution fixed these errors and the text was cleaned up in other 
  14. ways.  More complete input sensitivities were reported.  This version 
  15. includes subsequent perspective after use of OE's M1 handicounter (see 
  16. the M1 product review of this same date -- it is a pared down version of 
  17. the 3000A). Damien Thorn (Internet drdamien@delphi.com) wrote a non-tech-
  18. nical review article on several of OE's products (covering more why you'd 
  19. want them and what to do with them once you own them) that appeared in 
  20. the August 1993 issue of Nuts & Volts.
  21.  
  22. >>> ABSTRACT
  23. A 10Hz-3GHz feature-laden counter/timer/frequency meter could be a good 
  24. addition to your shack if you don't have the functionality yet. There are 
  25. some disallowed configurations that give you less than you may think if 
  26. you casually read the laundry list of features.  Input specifications 
  27. need more attention or at least acknowledgement of real-life problems.
  28.  
  29. >>> CONSTRUCTION
  30. The case is an extruded U-channel of aluminum with a flat top plate and 
  31. end plates.  The end plates screw into the U-channel with four screws, 
  32. one of which is a machine screw.  This one is by the A input, apparently 
  33. designed to provide a better "bite" into an interior copper shielding 
  34. plate around the A input.
  35.  
  36. A single 9.2cm x 12.6cm circuit board lies under the faceplate, directly 
  37. mounting the three buttons and six slide switches, which, in turn, poke 
  38. through the front plate.  A piggyback (piggyfront?) board holds the LCD 
  39. display.  There are two main chips--the OE10 vaulted in Optoelectronics' 
  40. marketing literature and an SC87C51.  My 8751 is labeled M1.3000A 5.20.93 
  41. VER 2.1 with a little sticky label.  The two main chips and a transformer 
  42. on the board have a white chalky substance around them as if they were 
  43. hand soldered and the flux vapors weren't cleaned off.  Hope it doesn't 
  44. corrode.  Probably 200 additional components, mostly surface mounted, 
  45. also occupy the circuit board.
  46.  
  47. The six batteries are stuck to the back shell (double sided tape?).  The 
  48. two battery wires terminate on the circuit board with a separable connec-
  49. tor.  The batteries' weight and the solid aluminum case give the unit a 
  50. solid feel.  Neither the wall-wart charging unit or the 3000A itself have 
  51. a charging light.  For the extra resistor and LED, I would like one.  Too 
  52. many times I've had some master switch, wall switch or loose plug inad-
  53. vertently negate my effort to charge batteries.  And when do you find 
  54. out?  When you needed the unit to be charged.
  55.  
  56. There are three plastic sheets stuck on the external top and face of the 
  57. unit.  My top piece was peeling off slightly.  The front bottom one was 
  58. crooked enough to let Button 2 not bounce back up.  Slight trimming fixed 
  59. that.  I can't tell if the white lettering is applied on top of the plas-
  60. tic or behind the plastic.  I hope it's behind so that they don't wear 
  61. off.  All the aluminum is painted black --not drippy, but it has the ap-
  62. pearance of thick enamel.  Personally, I would much rather have black 
  63. anodized so there would be no possibility of chipping paint.
  64.  
  65. >>> OWNER'S MANUAL
  66. It's five sheets of photocopied 8-1/2" x 11", printed in landscape mode 
  67. and folded in half.  It's short, but operation of the 3000A is easy, so 
  68. maybe a lot isn't needed.  I would propose inclusion of a few diagrams 
  69. and tables rather than all linear text description.  Included in the man-
  70. ual are:
  71.  
  72.      Features description............... 2 pages
  73.      Specifications..................... 1 page
  74.      Operation.......................... 2 pages
  75.      Data Interface..................... 2 pages
  76.      Block schematic.................... 2 pages
  77.      Operation hints.................... 4 pages
  78.      Battery & Power.................... 1 page
  79.      Calibration........................ 1 page
  80.      Warrantee.......................... 1 page
  81.      Service & Return................... 1 page
  82.  
  83. A loose sheet of paper describes how to turn on the backlight option.
  84.  
  85. I wanted to know what I could plug into this meter.  Nowhere in the specs 
  86. or owner's manual are the max input ratings. After talking with the fac-
  87. tory (toll call is small compared to the purchase price, but still is 
  88. annoying), I find the 1 Mohm inputs can handle a maximum on the order of 
  89. 50 volts AC+DC.  The Model 3000 (not the 3000A) specified 100V RMS as the 
  90. maximum.  Anyhow, I feel good about plugging in TTL.
  91.  
  92. DON'T plug TTL into the inputs if the 50 ohm switch is selected!  More 
  93. subtly, be sure you *unplug* it before you slide the switch to the 50 ohm 
  94. position.  The same phone call revealed that the 50 ohm inputs handle a 
  95. maximum of +15 dBm. That's 1.2 volts RMS in a 50-ohm system, correspond-
  96. ing to 3.4 volts Peak-to-Peak if the waveform is a sine wave.  Another 
  97. user was told by a factory technician that "a 5W HT connected to the 
  98. counter input for a short time would not damage the counter."  Five watts 
  99. is about +37 dBm!  Does the amount of time matter?  The correct numbers 
  100. need to be in an Owner's Manual, especially since the warranty excludes 
  101. "damage to the input circuitry from the application of an excessive input 
  102. signal."
  103.  
  104. I would suggest making no direct electrical connections to the 50 ohm 
  105. amps.  Only antenna type inputs should be used when the 50 ohm amps are 
  106. selected.  I've wrapped an 8" wire (snake like) around cordless phone 
  107. antennas, and that works ok, but even this would be *way* to much for a 
  108. 100W HF transmitter.  Be careful.  Full scale bar graph ranges from 2 - 4 
  109. mV, depending on the frequency.  If you stay on scale, you're safe, but 
  110. most of the valid input window is above "full scale."  In the range 4 mV 
  111. to approximately 1200 mV, you'll be increasing power "in the blind."
  112.  
  113. >>> OPERATION
  114. Some non-obvious combinations of functions and inputs is the order of the 
  115. day.  This is kind of weird, but is intentional to give you the best sen-
  116. sitivity possible, using a number of specialized input amps.
  117.  
  118. Turn it on, holding down a Button 2 if you want the optional backlight to 
  119. come on.  Button 3 selects the gate time (resolution).  With a slide 
  120. switch, you select either 1 Mohm (Hi-Z) or 50 ohm (Lo-Z) amplifiers.
  121.  
  122. If you select Hi-Z inputs, Button 1 selects either/both A and B inputs.  
  123. Button 2 rotates between FREQUENCY, PERIOD, INTERVAL, and RATIO.  Input A 
  124. measures only 10Hz - 50MHz, with sensitivity of a few tens of millivolts.  
  125. Input B measures only 10Hz - 10MHz, with a sensitivity of better than ten 
  126. millivolts.
  127.  
  128. If you select Lo-Z inputs, a signal strength bar-graph indication auto-
  129. matically appears and you must select one of three input amps:
  130.  
  131.     Input A only, from 10MHz - 220MHz (0.3 to 5mV sensitivity)
  132.     Input A only, from 10MHz - 880MHz (divide by 4 prescaler)
  133.     Input B only, from 500MHz - 3000MHz (new amp, div by 16 prescaler)
  134.  
  135. On one of OE's product literature flyers, they speak of a 1-200MHz input.  
  136. A phone call confirmed that this range exists only as a typo on the pro-
  137. duct literature flyer.
  138.  
  139. In parallel with all the above input selections, two switches let you 
  140. operate in either of four modes.  I'll call them modes 00, 01, 10, and 
  141. 11, representing whether FILTER and CAPTURE, respectively, are off (0) or 
  142. on (1).
  143.  
  144.    00 (FILTER off, CAPTURE off)  Operates as described above.  This is 
  145.       the single mode of the original Model 3000.  Meter shows updated 
  146.       values even if it's counting noise.  Gate light blinks continuous-
  147.       ly.
  148.  
  149.    10 (FILTER on, CAPTURE off)  PERIOD, INTERVAL and RATIO are disabled.  
  150.       Computer logic looks for meaningful oscillations, providing a new 
  151.       frequency value only if a legitimate count is acquired.  A higher 
  152.       level of filtering can be selected by holding down Button 3 during 
  153.       power up.
  154.  
  155.    11 (FILTER on, CAPTURE on)  Same as mode 10 except nothing happens 
  156.       until you arm the system by pressing Button 2.  Once you do this, 
  157.       the word "frequency" flashes on the display until a legitimate 
  158.       count is snagged.  A three-memory buffer (the display plus two 
  159.       more) keeps previous values.  They are referred to as X, A, and B.  
  160.       X contains the most recent, A the second most recent, and B the 
  161.       third most recent. When a fourth value is snagged, the value in B 
  162.       is lost.
  163.  
  164.    01 (FILTER off, CAPTURE on)  In this mode, no measurements are taken.  
  165.       Button 2 rotates between the three memories recorded in mode 11.
  166.  
  167. >>> PRODUCT SUPPORT
  168. In some sense, there's not much to support.  The meter either works or it 
  169. doesn't.  Operation is very straight forward.  I don't call to harass 
  170. service personnel and I *do* read the manuals first.  I did call to find 
  171. out about the input characteristics as discussed above and was, well, not 
  172. impressed.
  173.  
  174. Female answers and I ask for service or tech help.  After 2 minutes, the 
  175. line drops dead.  I call back.  Same female passes me on to Ray quickly 
  176. this time.  I ask Ray about input specs.  He says that, yes indeed, that 
  177. has been inadvertently left out of the manual.  Stand by.  Three minutes.  
  178. Ray comes back with info.  The 1 Mohm inputs are "plus 50 volt AC plus 
  179. DC", the 50 ohm inputs are "plus 15 dBm."  Yes, that's what I wanted!  
  180. Follow up:  What do you mean by 50v AC+DC?"  Hmmm.  He didn't know; 
  181. that's what the engineer told him.  Ok.  Is it capacitively coupled?  
  182. Uhh.. the inputs go right into a "MAR6 amplifier."  Could you please send 
  183. me a copy of just the front end prior to the MAR6 amps?  Pause... "Well, 
  184. there's a capacitor that goes to ground."  Yes, that's the kind of info I 
  185. want.  What size?  Maybe a pf or two?  "It's a 50v electrolytic."  Eeee  
  186. wrong person.  Would he send me just a copy of the front end schematic?  
  187. "No, we don't have anything like that I could send you."  Ok, well thanks 
  188. anyhow.  Bye.
  189.  
  190. In retrospect, I should have asked for the engineer who was sourcing this 
  191. information.  Inputs are listed in the specifications as 1MHz, 30pf.  
  192. This seems believable since it mimics a normal oscilloscope input.  But 
  193. are they AC or DC coupled? With what size, type & rating capacitor?  I 
  194. was hoping to use the INTERVAL or RATIO mode with Input B held open so I 
  195. can count events on Input A.  At Dayton a year back, I spoke with a man 
  196. named Bill Owens who seemed to have a good handle on the company's histo-
  197. ry and the capability of the product line.  I wish his knowledge was con-
  198. veyed better to potential buyers.
  199.  
  200. >>> REAL LIFE
  201. I have two regimes of interest for which I want this counter.  The first 
  202. is modem and ultrasonic work in the KHz to 100 KHz range.  The second is 
  203. radio VFO work, requiring MHz up to GHz.  I characterized the 3000A with 
  204. a 20Hz - 1MHz function generator, my Yaesu 757GX/Vectronics VC300DLP com-
  205. bo, and a Hewlett-Packard VHF/UHF generator.
  206.  
  207. --- low frequency ---
  208. For the less than 1MHz work, the Hi-Z inputs are used.  I have a 1MHz 
  209. TXCO standard in my shack that has an output floating on the back side of 
  210. a little toroid transformer.  It gives out approximately +-0.5v into my 
  211. 500 Kohm load (3000A and oscilloscope in parallel).  My 1MHz output shows 
  212. up as a stable 6.00 Mhz on the 3000A.  What?!  Yes.  Regardless of the 
  213. filter selection (none, medium, or full), six megahertz kept being dis-
  214. played.  The waveform was not symmetric, I'll give that much, but it was 
  215. very stable and clean from other high frequency hash.  It looked sort of 
  216. like this:
  217.  
  218.        |\      |\        The waveform stayed the same regardless of  
  219.  0 V___| --    | --      whether the 3000A was hooked up.  The 3000A 
  220.        |   |   |   |     counted the same regardless of whether the  
  221.       -.   .---.         o'scope was hooked up. P-P voltage was 1.5v.
  222.  
  223. The 1MHz output from my TXCO was a square wave ranging between 0 and 2 
  224. volts.  Regardless of the 3000A filter selection, it showed a frequency 
  225. of 3.0 MHz.  Another user working on a homebuilt oscillator also reports 
  226. extreme sensitivity to harmonics.  This harmonic sensitivity, combined 
  227. with extreme sensitivity makes the instrument virtually useless when us-
  228. ing any frequency multiples in your project:  you won't know which signal 
  229. is being locked onto.
  230.  
  231. I fired up a variable frequency / variable amplitude function generator 
  232. and o'scope combination.  The generator went to the scope with a BNC T-
  233. tap half way that plugged into the 3000A.
  234.  
  235. Using the A input, I needed incredulously large amplitudes--WAY above the 
  236. specified <20 mV.  Using the B input was even worse.  The procedure used 
  237. was to start at about 100 mV and go down first.  If a stable count held, 
  238. I reduced the PP voltage until spuratic readings were obtained.  If 
  239. 100 mV was giving spuratic or known-to-be-wrong numbers, I turned the 
  240. amplitude up until a stable reading was obtained.  The resultant measured 
  241. PP voltages (asterisks indicate I never was able to get a good count):
  242.  
  243.      Frequency      Input A             Input B
  244.      ---------      -----------         -------
  245.       20 Hz           2 V (0.78 VRMS)      *
  246.      200 Hz           1 V                  *
  247.      350 Hz           0.6 V                *
  248.       60 KHz          50 mV                4 V
  249.      500 KHz         <10 mV                1 V
  250.  
  251. Square wave counting was similar.  For instance, 2 V PP was needed at 
  252. 10 KHz to get a good count with Input A.  In all cases, the scope showed 
  253. clean signals with no high frequency hash.  Testing at another ham's 
  254. shack who had a fancy HP generator and scope yielded the same results 
  255. within 10%.  Stable operation of the Hi-Z input is mandatory to use the 
  256. interval and period functions of the 3000A, and this condition does NOT 
  257. seem to be met.  I consider the non-frequency modes to be historical car-
  258. ry-overs from the product lines' 7226 counter heritage rather than useful 
  259. features of OE's OE10 custom chip.
  260.  
  261. I own a PK232 radio modem and decided to see if the meter was good enough 
  262. to tune the audio tones.  With full output from the PK232 (about 0.5v PP 
  263. on the scope, giving 140mV RMS on a Fluke DVM good to 10KHz), I stuck the 
  264. tones into Input A and Input B with Hi-Z amps selected.  The 2200Hz tone 
  265. showed as 2265+-5Hz (A) and 23KHz (B), respectively.  The 1200Hz tone 
  266. showed as 1820+-15 (A) and 31KHz (B), respectively.  No, I did not adjust 
  267. the PK232.
  268.  
  269. --- high frequency ---
  270. My RF test goal was simple.  How accurate is my 757GX VFO?  Working near 
  271. 10MHz, the Lo-Z A input (only one suitable for this measurement) has an 
  272. advertised sensitivity of <5mV.  With a 12" dangling wire near the coax 
  273. out the back of the radio, the counter was dominated with a signal at 
  274. approximately 104 MHz (103.9 FM?).  Later tests 25 miles across town 
  275. again showed that with a wire pigtail antenna, it was being dominated 
  276. with this station.  I bought an RS15-577B FM trap and put it in line.  
  277. Now a 68 MHz interference dominates, probably the local Channel 4 TV 
  278. station.
  279.  
  280. I went back to the Hi-Z inputs.  At this point I was trying to determine 
  281. the electrical length of some coax.   A 1/4 wavelength of coax is termi-
  282. nated with a short circuit, and fed in parallel with a 50 ohm load with a 
  283. mid level RF power (see page 74 of the June 93 QST; the goal is to get a 
  284. 1:1 SWR).  The high current node at the terminator is the point I was 
  285. trying to pickup RF with the 3000A.  Twenty turns of perfboard wire 
  286. around a pencil stepped up the voltage enough for the meter to register 
  287. stable counts when the pickup coil was positioned near the end of the 
  288. coax shorting wire loop.
  289.  
  290. Characterization of the three 50-ohm amps with an HP generator showed 
  291. solid frequency locks at these random check points:
  292.  
  293.        Fast Amp              Middle Amp             Slow Amp
  294. ----------------------  ----------------------  ----------------------
  295.  800MHz, -47dBm, 1.0mV  100MHz, -65dBm, 0.12mV  150MHz, -60dBm, 0.22mV
  296. 1000MHz, -43dBm, 1.6mV  450MHz, -54dBm, 0.45mV
  297.  
  298. Attempts to do PERIOD, INTERVAL, and RATIO measurements were unsuccessful 
  299. due to the skittish behavior of the Hi-Z inputs.
  300.  
  301. >>> OPTIONS
  302. You can buy a precision (0.2 ppm vs 1.0 ppm) timebase for an extra $100.
  303. What used to be a $45 backlight option now seems to be a non-optional 
  304. extra expense.  September advertisements still quote the lower price for 
  305. the standard model, but the sales personnel won't sell one that way.
  306.  
  307. --- time base ---
  308. There are two reasons why I did not want to buy the precision time-base
  309. option.  One is because a RATIO mode is provided and I already have a 
  310. precision 10MHz TTL oscillator scavenged from an old LORAN navigation 
  311. board.  10MHz also happens to be the maximum frequency Input B accepted 
  312. in the ratio mode (all ratios are A/B).  What a coincidence.  Works for 
  313. me!
  314.  
  315. The second reason is simply that the 1ppm timebase is specified to age at 
  316. a rate of 1ppm/year.  A 0.2 ppm option would be degraded to the 1.0ppm 
  317. option in only about 10 weeks.  In any case, I usually don't need to know 
  318. the last 2 Hz on a 10000000 Hz signal.
  319.  
  320. --- backlight ---
  321. When it's on, I can hear a switching circuit bringing up a high voltage 
  322. for the luminescent display.  It turns off after 10 seconds of inactivity 
  323. and comes on again when some button is pressed or frequency is acquired.
  324.  
  325. It looks good.  Worth $45? The native display is plenty readable and the 
  326. extra light actually makes reading it harder from angles "above" the 
  327. counter.
  328.  
  329. >>> GOTCHAS
  330. The serial interface is unidirectional.  You send it a CR and it sends 
  331. back 10 digits and a decimal point, in ASCII, 2400bps, 8 bits, no parity, 
  332. 1 stop bit.  It only works in FREQ mode.  It provides only the most re-
  333. cent number, with no indication of whether this is another sample or the 
  334. same number it just sent you after your last request.  The interface can 
  335. sink 1.6mA and source 0.06 mA.
  336.  
  337. Excellent amplifier sensitivity isn't everything.  Sometimes it's even a 
  338. burden.  For decent counting, the signal you're monitoring must exceed 
  339. the noise (combination of *all* other RF signals in the bandpass of the 
  340. selected amp) floor by 10-15dB.  Specified sensitivity ranges from -57dBm 
  341. to -11dBm.  The input amp is limited to +15dBm.  Ambient noise, including 
  342. FM stations hovers about -11dBm.  Play with those numbers and you'll see 
  343. that the window for a good count can be pretty small. Try to measure a 
  344. cordless phone near your transmitter or computer monitor?  Probably not.  
  345. If you live near a broadcast station, good luck.  I don't consider these 
  346. numbers a design flaw given the intentionally wide frequency range of the 
  347. amps, but it definitely affects your day-to-day operation.
  348.  
  349. In Damien's review, he emphasizes the importance of a limited bandwidth 
  350. antenna.  Take this recommendation seriously.  Wide range frequency cov-
  351. erage means susceptibility to noise.  A bandwidth limiting antenna helps 
  352. mitigate this problem.
  353.  
  354. >>> SUMMARY
  355. The at-your-door price for a 3.5" x 5" circuit board seems a bit high, 
  356. but the counter is specified to do what I need it to do, plus a few 
  357. options.  Resolving the skittish Hi-Z input problems is a must.  The M1 
  358. gets around this by simply not having multifunction capability.  Paying 
  359. the extra $100 for a 3000A with specified capabilities that in real life 
  360. are marginally usable deserves a second thought. 
  361.  
  362. All models are available only direct from the manufacturer in Florida. 
  363. Contact Optoelectronics: 5821 NE 14th Avenue, Ft Lauderdale, FL 33334.  
  364. 800-327-5912 or 305-771-2050.  FAX 305-771-2052.  Makes you want to 
  365. dial ..2051 and see who you get, doesn't it? :) 
  366.  
  367. 73, Brian Mork (Opus-OVH)     ARO KA9SNF@wb7nnf.#ewa.wa.usa
  368.                               Internet BMORK@opus-ovh.spk.wa.us
  369.                               6006-B Eaker, Fairchild, WA 99011
  370.  
  371. ---
  372. Brian Mork UUCP bmork@opus-ovh.spk.wa.us / ARO ka9snf@wb7nnf.#ewa.wa.usa